The perfect blend of hi-tech and ease of use; ideal for testing residential and commercial buildings and enclosures where quality, appearance and performance counts.

Retrotec Model Q56 consists of a 2 channel DM-2A digital gauge with automatic control, umbilical connection cord, a 2200 Automatic Fan with low flow plates and a rapid set-up hard door panel in a case. Many fan case options.

DM-2A measures and controls pressure and air-flow automatically. Air-change rate, ELA or air-flow per unit area results without a computer!

2200 Fan has 7 calibrated flow ranges for leakage measurement of super tight to super leaky buildings. Available in 110 and 240 Volts.

Fan Flow (accuracy +/- 5%, +/- 3% with Auto-Correct in Retrotec software)

CFM

Liters/ s

m 3 / h

Maximum Flow in Free Air

6,300

2,973

10,705

Maximum Flow at 50 Pascal test pressure

5,600

2,643

9,514

Minimum Flow on Range Configuration C1 at 10 Pa

38

18

65


Dimensions

inches

cm

Fan height

26

66

Fan Depth

9.5

24.1

Fan Inlet diameter

22

56

Panel height

76.5 to 87

194 to 221

Panel Case (included)

31 × 30 x 7

77 × 76 × 18

Panel width

28.5 to 41.5

72.4 to 105.4


Fan weight

34 lb.

15.4 kg.

Fan Motor

0.75 hp, 9.8 amps at 120 V
4.5 amps at 240 Volts

Panel weight

21.5 lb.

9.8kg.